Oil fleet CCS#

Alt text

Technology ID: OIL_FLEET_CCS

Input energy interface, with default energy:

  • FUEL_CONSUMPTION: oil

Output energy interface, with default energy:

  • SYNC_RESERVE_DOWN: syncResDown

  • MFRR_DOWN: mfrrResDown

  • CO2: co2

  • CO2_CAPTURED_PRODUCTION: co2_captured

  • SYNC_RESERVE_UP: syncResUp

  • MFRR_UP: mfrrResUp

  • PRODUCTION: electricity

Technology behaviors:

  • OPTIM_PATHWAY

  • OPTIM_PMAX

  • FUEL

  • CLUSTER

  • RESERVE

  • UNIT

  • RETROFIT_CCS

Technology parameters:

ID

Label

Unit

Behaviors

Description

RATIO_CC

Carbon capture ratio

%

Carbon capture ratio

CONV_CAPACITY

Capacity conversion

RETROFIT_CCS or RETROFIT_H2

CCS Capacity conversion

SYNC_RESERVE_UP_MAX_SHARE

Max share to upward sync. reserve

%

RESERVE

Maximal share of upward sync. reserve in running capacity

SYNC_RESERVE_DOWN_MAX_SHARE

Max share to downward sync. reserve

%

RESERVE

Maximal share of downward sync. reserve in running capacity

MFRR_UP_MAX_SHARE

Max share to upward reserve

%

RESERVE

Maximal share of upward mFRR and sync. reserve in running capacity

MFRR_DOWN_MAX_SHARE

Max share to downward reserve

%

RESERVE

Maximal share of downward mFRR and sync. reserve in running capacity

SYNC_RESERVE_UP_COST

Op. cost of the upward sync. reserve

Euro/MW

RESERVE

Operating cost of the upward sync. reserve<

SYNC_RESERVE_DOWN_COST

Op. cost of the downward sync. reserve

Euro/MW

RESERVE

Operating cost of the downward sync. reserve

MFRR_UP_COST

Op. cost of upward mFRR

Euro/MW

RESERVE

Operating cost of upward mFRR

MFRR_DOWN_COST

Op. cost of downward mFRR

Euro/MW

RESERVE

Operating cost of downward mFRR

CAPEX_OVERNIGHT

CAPEX Overnight

Euro/MW

-Overall capital expenditure (only used for pathway optimization)

DEINVEST_COST

Deinvest cost

Euro/MW

Deinvest cost (only used for pathway optimization)

LIFETIME

Lifetime

Lifetime of the asset (only used for pathway optimization)

YIELD_INVEST

Yield of investment

%

Yield associated with investment

INSTALL_MAX

Max installation

MW

OPTIM_PATHWAY

Max installation (only used for pathway optimization)

DECOMM_MAX

Max decommissioning

MW

OPTIM_PATHWAY

Max decommissioning (only used for pathway optimization)

MIN_ON_TIME

Min on time

h

UNIT

When an asset in Unit Mode is switched ON it cannot be turned OFF before min On time.

STARTUP_TIME

Start up time

h

UNIT

Time an asset in Unit Mode takes to make a transition between OFF state and ON state. At the end of this duration, asset is at runningCapacityMinLoad*pMax.

STARTING_COST

Starting cost

Euro

UNIT

Fixed cost in euros associated to start an asset in Unit Mode. Is applied to any transition leading to state ON

STOPPING_COST

Stopping cost

Euro

UNIT

Fixed cost in euros associated to stop an asset in Unit Mode. Is applied to any transition leading to state OFF

CAPEX

CAPEX

Euro/MW/Year

Capital expenditure (only used for capacity optimization)

FOC

Fixed Operating Costs

Euro/MW/Year

Fixed Operating Costs (only used for capacity optimization)

PMAX

Pmax

MW

(not OPTIM_PMAX) and (not OPTIM_PATHWAY)

Installed power capacity

PMAXMIN

Min Pmax

MW

OPTIM_PMAX or OPTIM_PATHWAY

Installed capacity lower bound for capacity optimization

PMAXMAX

Max Pmax

MW

OPTIM_PMAX or OPTIM_PATHWAY

Installed capacity upper bound for capacity optimization

AVAILABILITY

Availability

%

Available capacity, expressed as a percentage of the installed capacity

VARIABLE_COST

Variable cost

Euro/MW.h

FUEL

Variable cost (fuel and emission costs excluded)

PRODUCTION_COST

Production cost

Euro/MW.h

not FUEL

Production cost (emission cost excluded)

FUEL_YIELD

Fuel yield w.r.t production

MW.h/MW.h HHV

FUEL

Yield between the production and the fuel consumption. For cluster and Unit behaviors, fuel yield is a function of the power output (and the running capacity in cluster mode) and this yield corresponds to the yield when the asset is at Pmax.

FUEL_YIELD_PMIN

Fuel yield at P min

MW.h/MW.h HHV

(CLUSTER or UNIT) and FUEL

Yield between the production and the fuel consumption when the Unit is at P min

FUEL_CO2_CONTENT

Fuel CO2 emissions

t/MW.h HHV

FUEL

Yield between the fuel consumption and the CO2 emissions

CO2_CONTENT

CO2 emissions

t/MW.h

not FUEL

Yield between the CO2 emissions and the production

MIN_LOAD

Fleet min load

%

not (CLUSTER or UNIT)

Minimum production level, expressed as a percentage of the available capacity

CLUSTER_STARTING_COST

Starting cost

Euro/MW

CLUSTER

Cost to start additional capacity

RUNNING_COST

Running cost

Euro/MW/h

CLUSTER

Cost associated with maintaining a certain running capacity

CO2_CONTENT_RUNNING_BOUND

CO2 emissions w.r.t. running capacity

t/MW.h

(CLUSTER or UNIT) and not FUEL

CO2 emissions with respect to running capacity

RUNNING_CAPACITY_MIN_LOAD

Running capacity min load

%

RESERVE or CLUSTER or UNIT

Minimum level for the production, expressed as a percentage of the running capacity in Cluster Mode and as percentage of available capacity (pMax*availabilty) inUnit Mode .For assets in fleet mode with reserve, please refer to addReserveProduction(..) for the running capacity definition.

MIN_OFF_TIME

Min off time

h

CLUSTER or UNIT

When a part of the running capacity is switched off, this part cannot be switch on before a duration equals to min Off time.

MFRR_UP_NOT_RUNNING_COST

Cost for not running upward mFRR

Euro/MW

RESERVE

Cost associated with the mfrr reserve procurement from non-running capacity

Model code:

stateON = AssetState('ON')
addFuelConsumption(asset, stateON)
addCo2Production(asset, stateON)
addEnergyProduction(asset, stateON)
addReserveProduction(asset, stateON, isQuickStart=True)
addUnitMode(asset, stateON)
finalize(stateON)