Geothermal fleet#

Alt text

Technology ID: GEOTHERMAL_FLEET

Output energy interface, with default energy:

  • SYNC_RESERVE_DOWN: syncResDown

  • MFRR_DOWN: mfrrResDown

  • CO2: co2

  • SYNC_RESERVE_UP: syncResUp

  • MFRR_UP: mfrrResUp

  • PRODUCTION: electricity

Technology behaviors:

  • OPTIM_PATHWAY

  • MUST_RUN

  • OPTIM_PMAX

  • RESERVE

Technology parameters:

ID

Label

Unit

Behaviors

Description

SYNC_RESERVE_UP_MAX_SHARE

Max share to upward sync. reserve

%

RESERVE

Maximal share of upward sync. reserve in running capacity

SYNC_RESERVE_DOWN_MAX_SHARE

Max share to downward sync. reserve

%

RESERVE

Maximal share of downward sync. reserve in running capacity

MFRR_UP_MAX_SHARE

Max share to upward reserve

%

RESERVE

Maximal share of upward mFRR and sync. reserve in running capacity

MFRR_DOWN_MAX_SHARE

Max share to downward reserve

%

RESERVE

Maximal share of downward mFRR and sync. reserve in running capacity

SYNC_RESERVE_UP_COST

Op. cost of the upward sync. reserve

Euro/MW

RESERVE

Operating cost of the upward sync. reserve<

SYNC_RESERVE_DOWN_COST

Op. cost of the downward sync. reserve

Euro/MW

RESERVE

Operating cost of the downward sync. reserve

MFRR_UP_COST

Op. cost of upward mFRR

Euro/MW

RESERVE

Operating cost of upward mFRR

MFRR_DOWN_COST

Op. cost of downward mFRR

Euro/MW

RESERVE

Operating cost of downward mFRR

CAPEX_OVERNIGHT

CAPEX Overnight

Euro/MW

-Overall capital expenditure (only used for pathway optimization)

DEINVEST_COST

Deinvest cost

Euro/MW

Deinvest cost (only used for pathway optimization)

LIFETIME

Lifetime

Lifetime of the asset (only used for pathway optimization)

YIELD_INVEST

Yield of investment

%

Yield associated with investment

INSTALL_MAX

Max installation

MW

OPTIM_PATHWAY

Max installation (only used for pathway optimization)

DECOMM_MAX

Max decommissioning

MW

OPTIM_PATHWAY

Max decommissioning (only used for pathway optimization)

CAPEX

CAPEX

Euro/MW/Year

Capital expenditure (only used for capacity optimization)

FOC

Fixed Operating Costs

Euro/MW/Year

Fixed Operating Costs (only used for capacity optimization)

PMAX

Pmax

MW

(not OPTIM_PMAX) and (not OPTIM_PATHWAY)

Installed power capacity

PMAXMIN

Min Pmax

MW

OPTIM_PMAX or OPTIM_PATHWAY

Installed capacity lower bound for capacity optimization

PMAXMAX

Max Pmax

MW

OPTIM_PMAX or OPTIM_PATHWAY

Installed capacity upper bound for capacity optimization

AVAILABILITY

Availability

%

Available capacity, expressed as a percentage of the installed capacity

PRODUCTION_COST

Production cost

Euro/MW.h

Production cost (emission cost excluded)

CO2_CONTENT

CO2 emissions

t/MW.h

Yield between the CO2 emissions and the production

Model code:

stateON = AssetState('ON')
addEnergyProduction(asset, stateON)
addCo2Production(asset, stateON)
addReserveProduction(asset, stateON, isFleetModeEnabled=True)
finalize(stateON)