Electric vehicles#
Technology ID: ELECTRIC_VEHICLES
Input energy interface, with default energy:
CONSUMPTION: electricity
Output energy interface, with default energy:
SYNC_RESERVE_DOWN: syncResDown
MFRR_DOWN: mfrrResDown
SYNC_RESERVE_UP: syncResUp
MFRR_UP: mfrrResUp
PRODUCTION: electricity
Technology behaviors:
USE_ENERGY_PRODUCTION
MUST_RUN
RESERVE
Technology parameters:
ID |
Label |
Unit |
Behaviors |
Description |
---|---|---|---|---|
ARRIVALS |
Percentage of EV arriving at terminal |
% |
Percentage of vehicles arriving at terminal |
|
EV_RECHARGE |
Average journey discharge |
kWh |
Average journey discharge |
|
EV_PMAX_IN |
Average charging capacity |
kW |
Average charging capacity per vehicle |
|
INPUT_EFFICIENCY |
Input efficiency |
% |
Pumping efficiency |
|
INITIAL_CONNECTED_EV |
Percentage of connected EV at t=0 |
% |
not MUST_RUN |
Percentage of connected EV at t=0 |
DEPARTURES |
Percentage of EV leaving from terminal |
% |
not MUST_RUN |
Percentage of vehicles leaving from terminal |
EV_STORAGE_CAPACITY |
EV storage capacity |
kWh |
not MUST_RUN |
EV storage capacity |
STORAGE_COST |
Storage cost |
Euro/MWh/h |
not MUST_RUN |
Cost associated with storage. Non-zero storage cost prevents equaly-optimal \ |
EV_PMAX_OUT |
Average V2G discharging capacity |
kW |
USE_ENERGY_PRODUCTION and not MUST_RUN |
Average Vehicle-to-grid discharging capacity |
OUTPUT_EFFICIENCY |
Output efficiency |
% |
USE_ENERGY_PRODUCTION and not MUST_RUN |
Turbining efficiency |
PRODUCTION_COST |
Production cost |
USE_ENERGY_PRODUCTION and not MUST_RUN |
Production cost (emission cost excluded) |
|
SYNC_RESERVE_UP_MAX_SHARE |
Max share to upward sync. reserve |
% |
RESERVE and not MUST_RUN |
Maximal share of upward sync. reserve in running capacity |
SYNC_RESERVE_DOWN_MAX_SHARE |
Max share to downward sync. reserve |
% |
RESERVE and not MUST_RUN |
Maximal share of downward sync. reserve in running capacity |
MFRR_UP_MAX_SHARE |
Max share to upward reserve |
% |
RESERVE and not MUST_RUN |
Maximal share of upward mFRR and sync. reserve in running capacity |
MFRR_DOWN_MAX_SHARE |
Max share to downward reserve |
% |
RESERVE and not MUST_RUN |
Maximal share of downward mFRR and sync. reserve in running capacity |
SYNC_RESERVE_UP_COST |
Op. cost of the upward sync. reserve |
Euro/MW |
RESERVE and not MUST_RUN |
Operating cost of the upward sync. reserve< |
SYNC_RESERVE_DOWN_COST |
Op. cost of the downward sync. reserve |
Euro/MW |
RESERVE and not MUST_RUN |
Operating cost of the downward sync. reserve |
MFRR_UP_COST |
Op. cost of upward mFRR |
Euro/MW |
RESERVE and not MUST_RUN |
Operating cost of upward mFRR |
MFRR_DOWN_COST |
Op. cost of downward mFRR |
Euro/MW |
RESERVE and not MUST_RUN |
Operating cost of downward mFRR |
TOTAL_EV |
Total number of EV |
EV |
Total number of vehicles |
|
Model code:
stateON = AssetState('ON')
setElectricVehiclesModel(stateON, asset)
finalize(stateON)