Behavior documentation¶
In Artelys Crystal Super Grid, most of the technologies have several modelling variations, also called “behaviors”. In order to activate one or the other variation of the model, the user may select the wanted behaviors for each asset via the Parameter tables.
The possible behaviors depend on the current technology and context type (for example, OPTIM_PMAX is only available for technologies that have a PMAX attribute, and in capacity optimization contexts).
The complete list of possible behaviors is available here:
ID | Label | Compatible context types |
---|---|---|
CLUSTER | Enables cluster modelling for this asset (linearisation of startup and running costs ) | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
CONSTANT_VAR | Force constant a temporal variable | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
DCOPF | Enable a Direct Current Optimal Power flow approach | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
DISCHARGE_TIMES | Enables the definition of the storage capacity with a discharge time (storage capacity = discharge time * max generation) | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
EQUALITY_CONSTRAINT | Changes the minimum RES generation constraint into an equality constraint | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
FLOW_BASED | Includes the selected transmission into flow-based market coupling constraints | PATHWAY_SIMULATION, SIMULATION |
FUEL | Activates the explicit modelling of the fuel consumption of the asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
GAS_BACKUP_HEATER | Use a gas backup heater (instead of an electric back-up) in the heat pump asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
GRADIENTS | Enables gradient constraints for this asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
MFRR_DOWN | Enables the participation to downward mFRR of the DSR asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
MFRR_UP | Enables the participation to upward mFRR of the DSR asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
MUST_RUN | Forces the asset to produce up to its availability (must run energy source) | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
OPTIM_PATHWAY | Enables optimization of the capacity of the asset during pathway optimization | PATHWAY_OPTIM |
OPTIM_PMAX | Enables the economic optimisation of the capacity of this asset | OPTIM_CAPA |
REPOWERING | Enables repowering of the asset during pathway optimization | PATHWAY_OPTIM |
RESERVE | Enables reserve allocation modelling for this asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
RETROFIT_CCS | Enables CCS asset retrofitting | OPTIM_CAPA, PATHWAY_OPTIM |
RETROFIT_H2 | Enables asset retrofitting to hydrogen | OPTIM_CAPA, PATHWAY_OPTIM |
SYNC_RESERVE_DOWN | Enables the participation to downward synchronized reserve of the DSR asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
SYNC_RESERVE_UP | Enables the participation to upward synchronized reserve of the DSR asset | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
UNIT | Enables Unit Commitment modelling (binary variables to describes asset states, startup and shutdown costs, minimal state durations and variable yields) | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
USE_ENERGY_PRODUCTION | Enables vehicle to grid production | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
USE_PMAX_IN | Enables the definition of an input power capacity (pmaxIn) different from the generation capacity (Pmax) | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
VOLUME_TARGET | Force a minimum or maximum volume of export/import | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |
WITH_IMPORT_EXPORT | Includes fixed imports/exports contracts in the national import/export balance constraint | OPTIM_CAPA, PATHWAY_SIMULATION, SIMULATION, PATHWAY_OPTIM |